| Expressible Moisture Index | to Top |
Reagents and Equipment:
|
Carver hydraulic press Plexiglass plates Whatman #1 filter paper [11.0 cm diameter] meat sample [275- 325 mg] metal spatula or scalpel compensating polr planimeter or Licor Model 3100 Area Meter [Forestry Research laboratory] |
Procedure:
| 1. | In duplicate, accurately weigh 275 - 325 mg meat sample on a filter paper. Place the filter paper and sample between two plexiglass plates, stacking the plates according to the number of samples. |
| 2. | Place samples and plates on a carver press and apply 5,000 psi over a 5 minute period. |
| 3. | After 5 minutes, release pressure and remove saples. Immediately trace the meat area and meat + juice area with a pencil for each sample. |
| 4. | After the samples are dry, determine the areas using a compensating polar planimeter or a Licor Area Meter. |
| 5. | Calculations: |
| REFERENCES | to Top |